HP 2392A [ POINT-TO-POINT WORKSTATION I O Reference Manual ]

POINT-TO-POINT WORKSTATION I O Reference Manual
HP 2392A
DIRECT CONNECTION, CHARACTER MODE
MPE I/O CONFIGURATION
Device Name: ATP, ATP37 HPTERMATP
(MPE G.01.00
or Later) ADCC HPTERMADCC
Device Type: 16
Subtype: ATP 0
ATP37 0
ADCC(HIOTERM2) 0
ADCC(HIOTERM0) 0, 4
ATC 0, 4
Terminal Type: 10 Standard for HP CRT terminals
18 For XON/XOFF protocol
MODE SELECTIONS
Line Modify OFF (no asterisk in label)
Modify all OFF (no asterisk in label)
Block Mode OFF (no asterisk in label)
Remote Mode ON (asterisk in label)
Smooth Scroll OFF (no asterisk in label)
Memory Lock OFF (no asterisk in label)
Display Functions OFF (no asterisk in label)
Auto LF OFF (no asterisk in label)
TERMINAL CONFIGURATION
Datacomm/Ext Dev Port 1/Port 2 (Not present if PORT2 not installed)
Keyboard USASCII
Terminal Id 2392A
Language English
Local Echo Off
Caps Lock Off *
Start Column 01 *
Bell On *
XmitFnctn(A) No
SPOW(B) No *
InhEolWrp(C) No *
Line/Page(D) Line
InhHndShk(G) No
InhDC2(H) No
Esc Xfer(N) No *
Field Separator US ([[CONTROL]]_)
Block Terminator RS ([[CONTROL]]^)
RETURN Def CR ([[CONTROL]]M)
TermMode HP
DATACOMM CONFIGURATION
ATP or ATP37
Baud Rate 300, 600, 1200, 2400, 4800, 9600, 19200
Parity/Data Bits NONE/8, 0's/7
EnqAck YES
Asterisk Off
Check Parity NO
SR(CH) Lo
RecvPace Terminal Type 10: None
Terminal Type 18: Xon/Xoff
XmitPace None
CS(CB)Xmit No
ADCC(HIOTERM2)
Baud Rate 300, 600, 1200, 2400, 4800, 9600
Other settings same as ATP.
ADCC(HIOTERM0)
Baud Rate
Speed-sensed: 300, 1200, 2400
Speed-specified: 300, 600, 1200, 2400, 4800, 9600
Other settings same as ATP.
ATC
Baud Rate 110, 150, 300, 600, 1200, 2400
Parity NONE, ODD, EVEN
Check Parity No parity: NO
ODD or EVEN parity: YES
Other settings same as ATP.
DIRECT CONNECTION, PAGE BLOCK MODE
Strap Settings and Block Mode may be changed programmatically.
MODE SELECTIONS
Block Mode ON (asterisk in label)
TERMINAL CONFIGURATION
Line/Page(D) Page
InhHndShk(G) Yes
InhDC2(H) No
MODEM CONNECTION
MPE I/O CONFIGURATION
Subtype: ATP 1
ATP37 1
ADCC(HIOTERM2) 1
ADCC(HIOTERM0) 1, 5
ATC 1, 5
NOTE Hewlett-Packard does not support the use of half duplex modems.
DATACOMM CONFIGURATION
Baud Rate selected must be supported by terminal, controller, and modem.
Refer to rates shown above and in the Table 12-7, Recommended
Asynchronous Full Duplex Modems, for possibilities.
CS(CB) Transmitting Yes (1)
Depends on type of modem used
Other configuration settings are the same as for direct connection.